Design and manufacturing of two interconnected nuclear glove boxes for experiments and corrosion studies in nuclear environment under purified inert atmosphere. High-capacity purification unit enabling residual contents below 5-10 ppm in oxygen and moisture in negative pressure conditions. High safety level with double HEPA filtration in glove boxes and all transfer systems and safety valves in case of containment break.